The Endura Grease Interceptor is the only moulded product available in the UK holding significant advantages over competitor systems. External reinforcing ribs on the single piece moulded tank provide strength and rigidity for "in-floor" installations and allow free circulation of airflow around the unit when installed "on-floor". IPEX Endura® Grease Management V As a plumbing appurtenance your Endura® grease interceptor MUST be isolated from the drainage system in the event that inal drain testing or other system pressure testing is required. DO NOT under any circumstances subject your interceptor to pressure test (AIR, WATER OR OTHERWISE). Endura Grease Interceptor 20 GPM /3 in. L Thermoplastic Grease Trap with Flow Control Device Installed in a drainage line between the Installed in a drainage line between the kitchen fixtures and the downstream sewer drainage system to intercept and store fat, oil and grease that can plug up the area sewage system. Is provided with a correctly sized flow control and complete installation.
The Endura Grease Interceptor is marked with “IN and Out” above the connections to ensure the grease interceptor is installed in the right direction. The grease interceptor should be installed as close as possible to the fixture(s) being served, as every foot of piping between the grease source and the interceptor is unprotected and a potential source for grease build-up. the air intake and the grease interceptor. For Grease Interceptor sizing, please reference the Sizing Guide or the Plumbing Drainage Institute Standard PDI-G Without a properly sized flow control, the flow through the interceptor may exceed the rating of the unit, causing lower efficiencies and allowing grease to pass through the. The Endura® XL grease interceptor and it associated products are the latest addition to the proven line of Endura® Grease Management products. We have spent many thousands of hours in the development of Endura® XL, our aim being simple – to produce the industry’s best Hydromechanical Grease Interceptor. From the ground up, Endura® XL.
or being operated as a PDI G installation. Endura XL grease interceptors are only to be installed in the manner and for the application shown. (fill in). A fl ow control with a rate of gpm will also be installed in accordance to manufacturer's instructions. The unit shall be comprised of engineered. Grease retention area. Water exits. Flow hits integral ramp Endura® Grease Interceptor performs like no other unit manufacturers instructions.
0コメント